• Home
  • Damp Proofing
  • Rising damp
  • Condensation
  • Dry rot
  • Wet rot
  • Woodworm
  • Local Branch
  • Contact Us
Peter Cox Blog | Property Advice
  • Home
  • Damp Proofing
  • Rising damp
  • Condensation
  • Dry rot
  • Wet rot
  • Woodworm
  • Local Branch
  • Contact Us
Home  /  Structural Repairs  /  Wall Ties and other Structural Repairs – A look at some of the methods of using wall ties for structural repairs
Surveyor inspecting wall for defects
16 March 2023

Wall Ties and other Structural Repairs – A look at some of the methods of using wall ties for structural repairs

Written by Jake Ryan
Structural Repairs cavity wall tie, structural damage, wall tie, wall ties Comments are off

The British Standard for wall ties – BS1243 was introduced in 1945 and was a ‘prescriptive’ standard – ie all ties had to conform to the approved design of the time, and the ‘butterfly’, ‘double triangle’ and ‘fish-tail’ were born. For cost saving, these were made from galvanised mild steel and it was only in the late 1990s that manufacturers applied for a relaxation in the ‘design’ element of the standard (DD140), so they could produce a competitively priced wall tie in stainless steel. At this time, in the worst cases of exposure and aggressive mortars, some mild steel ties were found to be corroding at an alarming rate of between 13-26 years.

Over 30 years ago, Professor Malcom Hollis calculated that over 12m cavity wall houses in the UK could be affected by wall tie corrosion to galvanised mild steel ties and, as a result, the ‘Preservation Industry’ has developed various neat and effective solutions to replace these ties.

Initially, these were ‘mechanical expanding anchors’ to tie both leaves of the wall back together again, or ‘resin ties’ where resin was used to bond both ends of a stainless steel tie to the masonry. Lately, drive ties, where an 8mm diameter helical anchor is forced into a 6mm diameter hole, are the norm.

Lateral restraints

Modern housing design incorporates lateral restraints (metal straps that connect the masonry to the floors and roof) to prevent lateral outwards movement of the masonry.

This, however, was not a requirement in older properties and while undertaking wall tie surveys we often see minor bulging of walls, where the building has moved over time. This can be controlled by the use of 12mm diameter stainless steel rods inserted from the outside and connecting to the first three parallel running joists, or in the case where joists bear into the affected wall – into joist noggins. The floor diaphragm thereafter ‘ties’ the wall back to the floor.

An alternative method is to use cementitious grout anchors. These are anchors contained within an inflatable woven sock. Once installed, the sock is inflated by pumping cementitious grout, which causes the sock to expand and lock the walls to the floors.

Lateral restraints are normally inserted at around 900mm horizontal centres, and once installed and neatly pointed, the holes are barely visible from a couple of metres.

Crack stitching

If the movement of a wall causes cracks then the cause of these must obviously be investigated and a cure implemented. The resultant cracked masonry or mortar joint can be stabilised and strengthened by the use of stainless steel helical bars, set into the mortar joint with a cementitious grout.

If you would like to know more about these services, visit our Specialist Expertise Page or call us free on 0808 273 2138.

Share On
Jake Ryan

Related Posts

  • Common furniture beetle

    DIY Woodworm Treatments: Can I Treat Woodworm Myself?

    June 24, 2025
  • Is Your Home Showing Signs of Cavity Wall Tie Failure? A Comprehensive Homeowner’s Guide

    May 5, 2025
  • Electric power meter with British currency

    Wanting lower energy bills this Autumn and Winter?

    October 24, 2023
  • terraced housing

    Enhancing Social Housing: The Benefits of Efficient Maintenance and Repairs

    August 3, 2023

Need some advice?

Talk to one of our experts:

0808 250 8820

Checking...

Ouch! There was a server error.
Retry »

Sending message...

Quick Form

Fill in the form below and we will be in touch soon


BLOG CATEGORIES

  • Black Mould
  • Condensation
  • Damp Problems
  • Damp Proofing
  • Dry Rot & Wet Rot
  • News
  • Structural Repairs
  • Waterproofing
  • Woodworm